The Fissnel FS2465&2466 Oxygen probes incorporate the world’s most rugged zirconia sensors. They are ideal for:

•Flue gas analysis

•Oxygen levels in boilers, kilns and furnaces

•Combustibles analysis

•Carbon potential measurement

•Water vapour concentration and dew point measurement

•Inert and sterile packaging

•General industrial use

•Annealing furnaces

酸露点传感器-750.jpg

The Fissnel FS2465 and 2466 probes are highly accurate, and have minimal drift (±1%). The Novatech in-situ probes are highly durable; choose the Fissnel 2465 for analysing gases with temperatures below 900ºC (1650ºF) and the Fissnel 2466 for temperatures ranging between 700°C and 1400°C (1290ºF to 2550ºF).

The Fissnel FS2465 and 2466 probes have a very rapid response to changes in Oxygen levels

With a response time of less than 4 seconds, potentially hazardous situations such as those caused through the build-up of dangerous fuel-rich conditions can be avoided.

The Fissnel FS2465 and 2466 probes are easy to install

The probes are inserted into the flue, or other measuring point, and the threaded nipple (FS2465 has 1.5“ BSPT/NPT; FS2466 has 3/4” BSPT/NPT) is screwed on to a mating socket welded to the process.

Connect the probe cable to the transmitter, and you are ready to measure and/or control the combustion process.


Sample Chamber for abrasive or corrosive processes

Certain processes, such as glass furnaces, ceramic furnaces or incinerators may contain highly corrosive particulate, abrasive or hostile compounds that will destroy any in-situ measuring device in short time.  By using a simple and inexpensive sample tube to extract a gas sample into a secondary sample chamber, accurate oxygen measurement can be achieved while reducing the exposure of the oxygen probe to the process environment.


Fissnel offers you safety of operation

The Fissnel FS2966 Oxygen Transmitter provides a main burner safety interlock. This is the ONLY reliable way of preventing potentially explosive situations.

Should the main burner fail or shut down then the sensor’s heater is de-energised so that dangerous flue gases cannot be ignited by the probe.


Specifications


FS2465 Heated Probe

FS2466 Unheated Probe

Applications

Combustion Flue gasses below 900°C (1650°F)

Combustion flue gasses above 700°C (1290°F) with no contaminants;
eg natural gas, light oils

Range of Measurement

100% to 1×10-30 Oxygen

Temperature Range

0°C to 900°C  (32°F to 1650°F)

700°C to 1100°C 253MA Stainless Steel
(1290°F to 2010°F)
700°C to 1400°C Alumina Ceramic
(1290°F to 2550°F)

Process Pressure Range

-50 kPa to 250 kPa

Probe Insertion Length

Standard Lengths:
250, 350, 500, 750, 1000, 1500mm
(10”, 14”, 20”, 30”, 40”, 60”)

Standard Lengths:
500, 750, 1000mm
(20”, 30”, 40”)

Process Connection

1.5” BSPT or NPT

3/4” BSPT or NPT

Outer Sheath

32mm OD 316 Stainless Stell, or 42mm with optional filter

19mm OD 253MA Stainless Steel or Alumina Ceramic

Electrical Connection

Weather-proof plug-in connector or optional screw terminals.
The plug connector can be supplied with the cable

Cable

FS2465 Cable can be supplied with a separate polyurethane reference airline

Heater

Yes

No

Internal Thermcouple

Type ‘K’

Typically Type ‘R’.
Also available with no TC, Type ‘S’ or Type ‘K’

Response Time

Typically <4 seconds

Typically <1 second

Head Temperature

-25°C to 100°C ( -15°F to 212°F) with standard terminations
-25°C to 150°C ( -15°F to 300°F) with optional ceramic terminal block

Reference Gas

Air 50 cc/minute approx. Pump can be supplied within transmitter

Calibration Check Gas Flow

Approx. 2 litres per minute

Reference Air Connection

1/4” tube

Integral air line through connector or 1.4” tube

Particulate Filter

Optional sintered titanium alloy
30 µm standard or 15µm extra fine

Not available

Calibration Check Gas Connection

1/8” NPT female

1/8” NPT female

Weight

approx. 2Kg + 165g per 100mm insertion length.
Exact weight will vary depending on electrical terminations and filters.

approx. 1.1Kg + 65g per 100mm insertion length

 


Previous article:No more
Next article:No more

Just take a look

CLASSIFICATION

  • Gas Analysers
  • Oxygen Probes
  • Moisture analyzer
  • Chromatographic analyzer
  • Tunnel sensor
  • Ultraviolet analyzer
  • Liquids Analysers
  • Steam Analysers
  • Compressed Air Analysers
  • Mass Flow Analysers
  • Thermal Energy Analysers
  • Concentration&Density Analysers